Alerts from control systems
When everything happens at once, what matters most gets lost.
SeMSe will receive alerts from the control system via API and send what matters as SMS and/or as a notification in the SeMSe app. The rest of the messages will be kept in the SeMSe log. SeMSe will go into production in 2027.
82 → 7
messages to the person on duty
About 90% fewer in the example, handled with the rules in SeMSe.
Example with fictitious data. Explanation below the example.
Same incident, two ways to be alerted
In the example, a control system sends 80 alerts from four power plants in just under four minutes. All of them go out as SMS.
Time 15:14:18
Plays for about 15 seconds
Without SeMSe
Everything is forwarded as SMS
82
Alerts from the control system
Text message
Kul Energi: 17.05.2025 15.08.24 Gulldammen Generator current L3 - High-high alarm, 354 A
15:10:36
Kul Energi: 17.05.2025 15.08.24 Gulldammen Cooling water valve position - High-high alarm, 55.0 %
15:10:37
Kul Energi: 17.05.2025 15.08.24 Gulldammen Generator apparent power - High-high alarm, 4150 kVA
15:10:45
Kul Energi: 17.05.2025 15.08.24 Gulldammen Grid voltage L2-L3 - High-high alarm, 15.6 kV
15:10:46
Kul Energi: 17.05.2025 15.08.24 Gulldammen Grid voltage L3-L1 - High-high alarm, 15.5 kV
15:10:47
Kul Energi: 17.05.2025 15.08.24 Gulldammen Grid voltage L1-L2 - High-high alarm, 15.5 kV
15:10:47
Kul Energi: 17.05.2025 15.08.24 Gulldammen Hour counter - High-high alarm, 50231 h
15:10:48
Kul Energi: 17.05.2025 15.08.24 Gulldammen Generator power factor - High-high alarm, 1.00 cosp
15:10:56
Kul Energi: 17.05.2025 15.08.24 Gulldammen Generator frequency - High-high alarm, 49.96 Hz
15:10:57
Kul Energi: 17.05.2025 15.08.24 Gulldammen Auto-stop power setpoint TM - High-high alarm, 500 kW
15:10:58
Kul Energi: 17.05.2025 15.08.24 Gulldammen Minimum flow l/s (calculated) - High-high alarm, 262.59 l/s
15:10:59
Kul Energi: 17.05.2025 15.08.24 Virrefoss G1 generator voltage L2-L3 - High-high alarm, 413 V
15:10:59
Kul Energi: 17.05.2025 15.08.24 Virrefoss G1 generator voltage L1-L2 - High-high alarm, 414 V
15:11:08
Kul Energi: 17.05.2025 15.08.24 Virrefoss G1 generator voltage L3-N - High-high alarm, 238 V
15:11:08
Kul Energi: 17.05.2025 15.08.24 Virrefoss G1 generator voltage L2-N - High-high alarm, 239 V
15:11:09
Kul Energi: 17.05.2025 15.08.24 Virrefoss G1 generator voltage L1-N - High-high alarm, 238 V
15:11:10
Kul Energi: 17.05.2025 15.08.24 Virrefoss G1 generator power factor - High-high alarm, 0.810
15:11:11
Kul Energi: 17.05.2025 15.08.24 Virrefoss G1 generator apparent power - High-high alarm, 578 KVA
15:11:18
Kul Energi: 17.05.2025 15.08.24 Virrefoss G1 generator active power - High-high alarm, 466 KW
15:11:19
Kul Energi: 17.05.2025 15.08.24 Gulldammen Generator current L1 - High-high alarm, 350 A
15:11:20
Kul Energi: 17.05.2025 15.08.24 Gulldammen Generator current L2 - High-high alarm, 352 A
15:11:21
Kul Energi: 17.05.2025 15.08.24 Gulldammen Generator voltage phase L3 - High-high alarm, 6.83 kV
15:11:21
Kul Energi: 17.05.2025 15.08.24 Gulldammen Generator winding L3 temperature 2 - High-high alarm, 50.4 °C
15:11:29
Kul Energi: 17.05.2025 15.08.24 Gulldammen Generator winding L2 temperature 2 - High-high alarm, 50.3 °C
15:11:30
Kul Energi: 17.05.2025 15.08.24 Gulldammen Generator winding L1 temperature 2 - High-high alarm, 48.5 °C
15:11:31
Kul Energi: 17.05.2025 15.08.24 Gulldammen Generator winding L3 temperature - High-high alarm, 50.6 °C
15:11:32
Kul Energi: 17.05.2025 15.08.24 Gulldammen Generator winding L2 temperature - High-high alarm, 50.9 °C
15:11:33
Kul Energi: 17.05.2025 15.08.24 Gulldammen Generator winding L1 temperature - High-high alarm, 50.88 °C
15:11:40
Kul Energi: 17.05.2025 15.08.24 Gulldammen Turbine flow - High-high alarm, 5.19 m3/s
15:11:41
Kul Energi: 17.05.2025 15.08.24 Gulldammen Total head - High-high alarm, 98.21 mWC
15:11:42
Kul Energi: 17.05.2025 15.08.24 Gulldammen Generator cold air temperature - High-high alarm, 19.8 °C
15:11:43
Kul Energi: 17.05.2025 15.08.24 Gulldammen Generator cold air temperature 2 - High-high alarm, 15.7 °C
15:11:44
Kul Energi: 17.05.2025 15.08.24 Gulldammen Generator voltage phase L2 - High-high alarm, 6.81 kV
15:11:51
Kul Energi: 17.05.2025 15.08.24 Gulldammen Generator active power - High-high alarm, 4139 kW
15:11:52
Kul Energi: 17.05.2025 15.08.24 Gulldammen Generator voltage phase L1 - High-high alarm, 6.83 kV
15:11:52
Kul Energi: 17.05.2025 15.11.50 Gulldammen G1 quick shutdown (QSD)
15:11:52CRITICAL
Kul Energi: 17.05.2025 15.08.24 Gulldammen Radial bearing (NDE) temperature - High-high alarm, 51.4 °C
15:11:53
Kul Energi: 17.05.2025 15.08.24 Gulldammen Thrust bearing (GSDE) temperature - High-high alarm, 49.5 °C
15:11:54
Kul Energi: 17.05.2025 15.08.24 Gulldammen Thrust bearing (TSDE) temperature - High-high alarm, 35.0 °C
15:12:02
Kul Energi: 17.05.2025 15.08.24 Gulldammen Radial bearing (DE) temperature - High-high alarm, 56.3 °C
15:12:03
Kul Energi: 17.05.2025 15.08.24 Gulldammen Generator hot air temperature - High-high alarm, 39.7 °C
15:12:04
Kul Energi: 17.05.2025 15.08.24 Gulldammen Hydraulic oil temperature - High-high alarm, 35.3 °C
15:12:05
Kul Energi: 17.05.2025 15.08.24 Blandevann G1 turbine flow - High-high alarm, 2.566 m3/s
15:12:06
Kul Energi: 17.05.2025 15.08.24 Blandevann Intake reservoir filling level - High-high alarm, 99.5 %
15:12:13
Kul Energi: 17.05.2025 15.08.24 Blandevann Intake reservoir volume - High-high alarm, 0.15 million m3
15:12:14
Kul Energi: 17.05.2025 15.08.24 Virrefoss G1 generator reactive power - Low-low alarm, -342 KVA
15:12:14
Kul Energi: 17.05.2025 15.08.24 Gulldammen Generator reactive power - Low-low alarm, -400 kVAr
15:12:15
Kul Energi: 17.05.2025 15.08.24 Virrefoss Intake minimum flow cm - High-high alarm, 25.2 cm
15:12:16
Kul Energi: 17.05.2025 15.08.24 Virrefoss G1 generator hour counter - High-high alarm, 22249 h
15:12:24
Kul Energi: 17.05.2025 15.08.24 Virrefoss G1 generator production year to date - High-high alarm, 5000000 KWh
15:12:25
Kul Energi: 17.05.2025 15.08.24 Virrefoss Intake water level downstream elevation - High-high alarm, 225.966 m a.s.l.
15:12:26
Kul Energi: 17.05.2025 15.08.24 Blandevann Intake reservoir precipitation capacity - High-high alarm, 0 mm
15:12:26
Kul Energi: 17.05.2025 15.08.24 Blandevann G1 turbine efficiency - High-high alarm, 89.9 %
15:12:27
Kul Energi: 17.05.2025 15.08.24 Blandevann Intake total river flow - High-high alarm, 2.63 m3/s
15:12:35
Kul Energi: 17.05.2025 15.08.24 Buksevann G1 turbine efficiency - High-high alarm, 93.3 %
15:12:36
Kul Energi: 17.05.2025 15.08.24 Buksevann G2 turbine efficiency - High-high alarm, 93.1 %
15:12:37
Kul Energi: 17.05.2025 15.08.24 Buksevann Reservoir volume - High-high alarm, 0.05 million m3
15:12:37
Kul Energi: 17.05.2025 15.08.24 Buksevann Reservoir filling level - High-high alarm, 120.6 %
15:12:38
Kul Energi: 17.05.2025 15.08.24 Buksevann Reservoir spillway flow - High-high alarm, 5.49 m3/s
15:12:46
Kul Energi: 17.05.2025 15.08.24 Buksevann Level measurement primary sensor HRV - High-high alarm, 20.6 cm
15:12:47
Kul Energi: 17.05.2025 15.08.24 Buksevann Total river flow - High-high alarm, 62.74 m3/s
15:12:48
Kul Energi: 17.05.2025 15.08.24 Virrefoss Intake water level upstream elevation - High-high alarm, 226.065 m a.s.l.
15:12:48
Kul Energi: 17.05.2025 15.08.24 Virrefoss Intake minimum flow l/s - High-high alarm, 45 l/s
15:12:49
Kul Energi: 17.05.2025 15.08.24 Virrefoss G1 generator speed percent - High-high alarm, 98.0 %
15:12:57
Kul Energi: 17.05.2025 15.08.24 Virrefoss Grid line voltage L3-N - High-high alarm, 238 V
15:12:58
Kul Energi: 17.05.2025 15.08.24 Virrefoss Grid line voltage L1-L2 - High-high alarm, 414 V
15:12:58
Kul Energi: 17.05.2025 15.08.24 Virrefoss Grid line voltage L2-N - High-high alarm, 238 V
15:12:59
Kul Energi: 17.05.2025 15.08.24 Virrefoss Grid line voltage L1-N - High-high alarm, 239 V
15:13:00
Kul Energi: 17.05.2025 15.08.24 Virrefoss G1 generator frequency - High-high alarm, 49.99 Hz
15:13:08
Kul Energi: 17.05.2025 15.08.24 Virrefoss G1 generator current L3 - High-high alarm, 805 A
15:13:08
Kul Energi: 17.05.2025 15.08.24 Virrefoss G1 generator current L2 - High-high alarm, 819 A
15:13:09
Kul Energi: 17.05.2025 15.08.24 Virrefoss G1 generator current L1 - High-high alarm, 806 A
15:13:10
Kul Energi: 17.05.2025 15.08.24 Virrefoss Grid line voltage L2-L3 - High-high alarm, 413 V
15:13:11
Kul Energi: 17.05.2025 15.08.24 Virrefoss Grid line voltage L3-L1 - High-high alarm, 413 V
15:13:19
Kul Energi: 17.05.2025 15.08.24 Virrefoss G1 turbine maximum opening - High-high alarm, 95 %
15:13:20
Kul Energi: 17.05.2025 15.13.18 Virrefoss Transformer protection critical
15:13:20CRITICAL
Kul Energi: 17.05.2025 15.08.24 Virrefoss G1 turbine guide vane position - High-high alarm, 89.40 %
15:13:20
Kul Energi: 17.05.2025 15.08.24 Virrefoss G1 generator winding L2 temperature - High-high alarm, 47 °C
15:13:21
Kul Energi: 17.05.2025 15.08.24 Virrefoss G1 generator winding L3 temperature - High-high alarm, 45 °C
15:13:22
Kul Energi: 17.05.2025 15.08.24 Virrefoss G1 generator radial bearing (NDE) temperature - High-high alarm, 31 °C
15:13:31
Kul Energi: 17.05.2025 15.08.24 Gulldammen Hydraulic oil pressure - High-high alarm, 95.9 bar
15:13:42
Kul Energi: 17.05.2025 15.08.24 Gulldammen Lubricating oil temperature - High-high alarm, 29.8 °C
15:14:18
With SeMSe
The rules decide what is sent
7
Alerts via SeMSe
Text message
Kul Energi: 17.05.2025 15.08.24 Gulldammen Generator current L3 - High-high alarm, 354 A
15:10:36NORMAL
Rule: First message from the power plant
Kul Energi: 17.05.2025 15.08.24 Virrefoss G1 generator voltage L2-L3 - High-high alarm, 413 V
15:10:59NORMAL
Rule: First message from the power plant
Kul Energi: 17.05.2025 15.11.50 Gulldammen G1 quick shutdown (QSD)
15:11:52CRITICAL
Rule: Critical is always sent, even from a power plant that has already been alerted
Kul Energi: 17.05.2025 15.08.24 Blandevann G1 turbine flow - High-high alarm, 2.566 m3/s
15:12:06NORMAL
Rule: First message from the power plant
Kul Energi: 17.05.2025 15.08.24 Buksevann G1 turbine efficiency - High-high alarm, 93.3 %
15:12:36NORMAL
Rule: First message from the power plant
Kul Energi: 17.05.2025 15.13.18 Virrefoss Transformer protection critical
15:13:20CRITICAL
Rule: Critical is always sent. Not confirmed within the deadline: escalated to the next group
Summary: 76 alerts held back and stored in the log (Gulldammen 35, Virrefoss 30, Buksevann 6, Blandevann 5)
After the incidentSUMMARY
Rule: Summary when the alerts have subsided. Deadline set by the customer
About the example
Example with fictitious data. Two critical messages have been added to show the rule. “Without SeMSe” shows traditional alerting, where everything is sent as SMS. “With SeMSe” shows what the rules in SeMSe would have done with the same incident. 82 messages become 7 during a hectic period of just under four minutes.
In the example, the first alert from each power plant and all critical alerts are sent to the person on duty. The “noise” is reduced by about 90%, and the person on duty can concentrate on the work in the control system. Also note the summary at the end.
How it will work
The rules will be set by the customer. Everything will be stored in a complete log. The logs will be exportable and can be processed, for example with AI, to assess trends or other patterns that go beyond a single control system.
One message per power plant
The first alert from each power plant will be sent. The rest will be held back in the log, and a summary will tell how many.
Critical messages will always get through
Messages the customer marks as critical, or with another word, will be able to receive special handling with different types of alerts and escalations.
Escalation to the next group
If no one confirms a critical message within the deadline, it will go on to the next group.
Minimum staffing
The customer will be able to set a requirement for a minimum number on duty in each group.
The control system sends out. Nothing comes in.
Alerts will go one way from the control system to SeMSe. No connection will be opened into the control system, and the person on duty works in the control system, not in SeMSe.
Control system
OT zone, sends out only
SeMSe
Rules, log and escalation
Person on duty
SMS and the SeMSe app
Fixed and predictable price
Price per message
SMS gateways usually charge per message. The bill then follows the fault situation, and an alarm flood becomes most expensive exactly when there is most to do.
Fixed price with SeMSe
SeMSe will have a fixed and predictable price, not a price per message.